RAS1620
Operational Procedures
Set-up Instructions
Required Materials and Tools
- No hand tools are required to operate unit, e.g. wrenches,
hammer, etc.
- Required materials to be separated from integral trailer unit
- One inflatable air shelter
- Two zip-in doors
- Two yellow expandable A/C ducts
- Two black straps to attach A/C ducts to air shelter
- Two ground cover tarps
- Air blower, air hose, and heat absorption foam pad for blower
- 115 volt power box
- Two water ballast tubes and fill hose
(recommended option)
Pre-Start Checklist
- Check fuel level for generator
- Check oil level for generator
- Check water level for ballasts (recommended option)
- Confirm house or generator power transfer switch
- Block trailer tires to inhibit trailer movement
- Remove and set ground stake
Generator Start/Controls
- Confirm all breakers and switches are on off mode
- Pull choke lever to full open
- Turn ignition switch to start mode and release
- Push choke lever back to full closed
- Close the following breakers (in this order)
- Engine exhaust fan
- Control power
- A/C unit
- Light pole (optional)
- 115 volt power outlet
- Turn-off (close) all rocker switches at control panel (in this
order)
- Engine exhaust fan
- A/C
- Light pole (optional)
- 115 volt power outlet
Air Shelter Set-Up
- Open back gate and release all hold down straps
- Place ground cover tarp
- Unroll air shelter on top of ground tarp
- Attach high pressure air inflation hose to air frame fill port
- Confirm all attritional air fill ports are closed
- Turn on air blower to inflate air shelter and provide assistance
to insure the air frame is not binding or caught in the shelter
- Attach (zipper) water ballast tube to air shelter (recommended
option)
- Attach hose from water tank to water ballast tube and fill with
water, and then repeat to second water ballast tube (recommended
option)
- Extend 115 volt power supply cord from trailer to shelter through
the accessory port (also the air fill port)
- Check connections on the supply and return air ducts
- Connect any lighting or internal devices to 115 volt power
supply
- Confirm proper generator operation at unit control panel
Tear Down Instructions
- Confirm all connections to generator
- Remove all items from inside shelter
- Confirm all people to be outside shelter
- Release high pressure air valve at back of shelter
- Connect vacuum side of air blower to high pressure fitting on
shelter
- Start high pressure fan and evacuate all air from structural tube
- Drain water from ballast tubes and detach water ballast tubes
- Detach doors and open door flaps and store in cabinet
- Detach supply and return air ducts and store in cabinet
- Detach vacuum hose from high pressure fitting
- Shut down generator and lower exhaust stack
- Neatly fold the air shelter into thirds and roll towards storage
cabinet
- Cover air shelter with protective trap for travel
- Secure straps inside shelter cabinet
- Lower light pole and secure to trailer
- Release ground stake and store in trailer frame
- Remove blocks from trailer tires
- Store all tarps and misc. parts in storage cabinet
- Lock all cabinet doors for travel
- Check for loose or missing parts
- Check trailer lights and trailer connection before moving
|

 |
|
Standard Sizes |
| Size |
Sq.Ft. |
12x10
12x15
16x15
16x20
16x20 Quattro |
144
240
320
640
1536 |
|



Click Here to
Download Brochure |